Skip to content

Remote-controlled light dimmer, remote-controlled socket – Kangtai

Serious risk Electric shock, Fire

Published by Safety Gate 9 Aug 2007In the weekly report of 10 Aug 2007 (week 31, 2007)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 8 min agoSource: EU Safety Gate
Product
Remote-controlled light dimmer, remote-controlled socket
Brand
Kangtai (3 alerts)
Type / model
Art. No 6899 B
Description
The test piece is a remote-controlled light dimmer set, consisting of a remote-controlled light dimmer and a remote-control device. Input voltage, output: 230 V AC 50/60 Hz, 300 W CE mark: present GS mark: present, ETS (on packaging).
Risk
This product poses a risk of electric shock because:- all four remote-controlled dimmers measured had, as supplied, an excessively wide gap between the earth contacts (between 29.4 mm and 30.7 mm). If this gap is too wide, a safe contact between connected appliances and the protective conductor is not ensured;- there is no indication of rated current. This product poses a risk of fire because when a test current of 20 amperes was connected to a product for the load test, there was an increase in temperature of more then 56°K. A short-circuit occurred on the printed-circuit board. This product does not comply with the Low Voltage Directive and the R&TTE Directive.
Measures
  • Withdrawal from the market and recall from consumers ordered by the authorities
Notifying country
Germany
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0802/07
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Other alerts for Kangtai

Sources

  1. Safety Gate alert 0802/07
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2007-31 (XML)
    the copy this page was built fromCC0 1.0