Skip to content

Portable lamp

Serious risk Electric shock, Fire

Published by Safety Gate 31 Aug 2008In the weekly report of 1 Sep 2008 (week 34, 2008)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked just nowSource: EU Safety Gate
Product
Portable lamp
Brand
Unknown
Type / model
type FL 003, EAN code 3858883938272
Description
. Ceramic table lamp, 220-240V~, 50Hz, 40W, with double insulation, class F.
Risk
The product poses a risk of electric shock and fire because : - the cross-sectional area of cord conductors is less than 0.2 mm2 which can cause heating and lead to fire,- cord anchorage is not effective and cord may pull out with force of 60 N, which means that the user can come into contact with live wires.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures
  • Sales ban ordered by the authorities
Notifying country
Slovenia
Country of origin
People's Republic of China
Alert type
Consumer
Photos