Cord extension set - Puutarhapistorasia AV-2005 – MY

Serious risk Electric shock

Published by Safety Gate 11 Sep 2008In the weekly report of 12 Sep 2008 (week 36, 2008)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 7 min agoSource: EU Safety Gate
Product
Cord extension set - Puutarhapistorasia AV-2005
Brand
MY
Type / model
Type: SGS-202G EAN: 6 417846 032470
Description
Cord extension set with two socket-outlets and a rubber cable of length 1.5 m.
Risk
The product poses a risk of electric shock because :- during various tests the cable showed cracks both at the sheath and in the insulation resulting in the wires of the conductors becoming accessible;- the temperature of the terminals rose in excess of 100 K in circuits L-earth, when it should not exceed 45 K;- The measured contact pressure of the earthing contacts is 0-4.9 N, when it shall not be less than 5 N;- the measured distance between the side-earthing contacts is 30.3 mm and 30.4 mm, which exceeds the requirement of 29 mm +0/-1 mm.The product does not comply with the Low Voltage Directive and with the relevant European standard EN 60811.
Measures
  • Withdrawal from the market and recall from consumers ordered by the authorities
Notifying country
Finland
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 0992/08Photo 2 of the product in Safety Gate alert 0992/08
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 0992/08
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2008-36 (XML)
    the copy this page was built fromCC0 1.0