Lighting chain - Luz de Navidad 140 Cabezas

Serious risk Electric shock

Published by Safety Gate 18 Oct 2007In the weekly report of 19 Oct 2007 (week 41, 2007)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Product
Lighting chain - Luz de Navidad 140 Cabezas
Brand
Unknown
Type / model
Ref. 7990056
Description
Christmas lighting chain with 1400 coloured bulbs. The packaging is a cardboard box with information on the distributor.
Risk
The product poses a risk of electric shock because:- the sample does not pass the electric strength test corresponding to Class II,- there is no reference indicating the kind of bulbs, - there is no statement that the bulbs cannot be replaced, - there is no origin mark, class II symbol, markings of the degree of protection against dust and damp or warning that the lights can be used indoors only on the bulb holder, cable or a label attached to the cable,- the luminaire does not have sufficient mechanical strength in that it does not pass the test with a spring–driven apparatus, leaving active parts accessible after the test,- the terminals do not pass the test for the efficiency of permanent connections,- the cable incorporated in the chain has characteristics inferior to those of the standard and the nominal section of the conductors, at 0.07 mm², is less than the 0.50 mm² required by the standard,- the cable does not pass the tensile test; the power plug does not comply with standard and the length of the cable between the plug and the first bulb, at 1.10 metres, is less than the 1.50 metres required by the standard,- it is not protected against the conditions of damp which may arise in normal use,- it does not pass the electrical rigidity test.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
Measures
  • Import rejected by the customs authorities
Notifying country
Spain
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 1058/07
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 1058/07
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2007-41 (XML)
    the copy this page was built fromCC0 1.0