DVD player – Denver

Serious risk Electric shock

Published by Safety Gate 22 Nov 2007In the weekly report of 23 Nov 2007 (week 46, 2007)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 8 min agoSource: EU Safety Gate
Product
DVD player
Brand
Denver (14 alerts)
Type / model
Type: DVD-736K, EAN: 5 706751 007378.
Description
Surround DVD player with karaoke. Class 1 laser product.
Risk
There is a risk of electric shock due to the fact that: - there is insufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched,- the secondary circuit can be touched through the output terminals,- creepage distances and clearances in the mains transformer between the primary windings and secondary windings / between the primary windings and the output winding wires of the secondary windings / between the secondary windings and output winding wires of the primary windings are less than 5 / 4 mm (measured a minimum 0.55 mm / 1.9 mm / 1.3 mm),- the windings are positioned concentrically on a single coil former, - all output winding wires are not insulated with the insulation tubes. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60065.
Measures
  • Sales ban, withdrawal from the market and recall from consumers ordered by the authorities. Press release has been issued
Notifying country
Finland
Country of origin
Unknown
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 1218/07Photo 2 of the product in Safety Gate alert 1218/07
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Other alerts for Denver

Sources

  1. Safety Gate alert 1218/07
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2007-46 (XML)
    the copy this page was built fromCC0 1.0