Skip to content

Lighting chain - Fairy lights with 100 lamps – PHU

Serious risk Electric shock, Fire

Published by Safety Gate 4 Dec 2008In the weekly report of 5 Dec 2008 (week 48, 2008)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 8 min agoSource: EU Safety Gate
Product
Lighting chain - Fairy lights with 100 lamps
Brand
PHU
Type / model
EL100MT, EL100MX
Description
Indoor chain of lights with 100 little jack lamps, extendable, with a Euro plug 230 V, 50 Hz, max. 35 W
Risk
The existing conductor cross section is about 0.15 mm², the required cross section is 0.5 mm², thus overload is possible, as the function is that of an extension cord with accompanying luminaire. The conductor insulation does not fulfill the requirements for double insulation according to EN 60598-2-20, thereby it can be easily damaged.
Measures
  • Withdrawal from the market ordered by the authorities
Notifying country
Germany
Country of origin
Unknown
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert 1423/08Photo 2 of the product in Safety Gate alert 1423/08
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert 1423/08
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2008-48 (XML)
    the copy this page was built fromCC0 1.0