Bus “CNG12; CNG10,5; NBG12; BNG 10,5; NSG12”
Serious risk Fire, Injuries
- Product
- Bus
- Name
- CNG12; CNG10,5; NBG12; BNG 10,5; NSG12
- Type / model
- e8*2007/46*0048*06
- e8*2007/46*0059*09
- e8*2007/46*0059*10
- e8*2007/46*0067*04
- e8*2007/46*0313*04
- Type / model as notified
- e8*2007/46*0048*06, e8*2007/46*0059*09, e8*2007/46*0059*10, e8*2007/46*0067*04, e8*2007/46*0313*04
- Batch numbers
- BNG 10,5, e8*2007/46*0048*06, 2019
- CNG 12, e8*2007/46*0059*09, 05/2019 - 12/2019
- CNG 12, e8*2007/46*0059*10, until 05/2020
- CNG10,5, e8*2007/46*0048*06, 2019
- NBG12, e8*2007/46*0067*04, 2019
- NSG12, e8*2007/46*0313*04, until 07/2020
- Description
- Bus
- Production dates
- BNG 10,5, e8*2007/46*0048*06, 2019 CNG 12, e8*2007/46*0059*09, 05/2019 - 12/2019 CNG 12, e8*2007/46*0059*10, until 05/2020 CNG10,5, e8*2007/46*0048*06, 2019 NBG12, e8*2007/46*0067*04, 2019 NSG12, e8*2007/46*0313*04, until 07/2020
- Risk
- The pressure relief device of the compressed natural gas (CNG) tank might not properly vent when necessary.Consequently, if the CNG tank is exposed to heat, it may break and leak gas increasing the risk of fire or explosion.
- Measures
- All Emer Pressure Relief Device (PRD valves) will be change · ordered on the manufacturer
- Notifying country
- Czechia
- Country of origin
- Czechia
- Alert type
- Professional
This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.