Skip to content

Particle filter mask – Tex-Tech “FFP2 respiratory mask high filtration efficiency”

Serious risk Health risk / other

Published by Safety Gate 10 Nov 2021In the weekly report of 12 Nov 2021 (week 45, 2021)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 6 min agoSource: EU Safety Gate
Product
Particle filter mask
Brand
Tex-Tech (3 alerts)
Brand as notified
TEX-TECH
Name
FFP2 respiratory mask high filtration efficiency
Type / model
FFP2 Premium
Batch
01102020/T
Barcode
8594176575094
Barcodes listed
8594176575094 (official alert record)
Description
White masks with ‘TEX-TECH FFP2 Premium’ labelling. The number 1040 appears next to the CE mark on the masks.
Risk
The particle/filter retention of the material is insufficient (measured values: as low as 83%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect. Furthermore, the physical resistance of the filtering material is too high (measured values of exhalation resistance: up to 3,8 mbar). Consequently, it may prevent a sufficient quantity of air to be exhaled, causing difficulties to breathe. The product does not comply with the Personal Protective Equipment (PPE) Regulation and with the relevant European standard EN 149.
Measures
  • Ban on the marketing of the product and any accompanying measures
  • Recall of the product from end users · by the retailer
Notifying country
Germany
Country of origin
Czechia
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert A12/01531/21Photo 2 of the product in Safety Gate alert A12/01531/21Photo 3 of the product in Safety Gate alert A12/01531/21Photo 4 of the product in Safety Gate alert A12/01531/21Photo 5 of the product in Safety Gate alert A12/01531/21
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Other alerts for Tex-Tech

Sources

  1. Safety Gate alert A12/01531/21
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2021-45 (XML)
    the copy this page was built fromCC0 1.0