Skip to content

Whipping siphon – JJA

Serious risk Injuries

Published by Safety Gate 5 Apr 2018In the weekly report of 13 Apr 2018 (week 15, 2018)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 9 min agoSource: EU Safety Gate
Product
Whipping siphon
Brand
JJA (3 alerts)
Type / model
136010
Batch numbers
  • 3560238905227/ M08698 and M09042
  • 3560238905234/ M08698 and M09042
  • 3560239259503 / M08698 and M09042
  • 3560239259510/ M08698
(official alert record)
Batch as notified
3560238905227/ M08698 and M090423560238905234/ M08698 and M090423560239259503 / M08698 and M090423560239259510/ M08698
Barcode
3560238905227, 3560238905234, 3560239259503, 3560239259510
Description
Culinary whipping siphon with a capacity of 500 ml, for making whipped cream, for example.
Risk
The pressure-relief valve on the head of the whipping siphon is defective. The valve could be ejected from the siphon causing injuries to the user.The product does not comply with the requirements of the Pressure Equipment Directive.
Measures
  • Recall of the product from end users · by the importer
Notifying country
France
Country of origin
Hong Kong
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert A12/0522/18Photo 2 of the product in Safety Gate alert A12/0522/18
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Other alerts for JJA

Sources

  1. Safety Gate alert A12/0522/18
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2018-015 (XML)
    the copy this page was built fromCC0 1.0