Swivel – DMM “Compact Swivel Range”
Serious risk Injuries
- Product
- Swivel
- Brand
- DMM (4 alerts)
- Name
- Compact Swivel Range
- Type / model
- Nexus 1 S-L (SW470), Nexus 2 S-S (SW480), Nexus 3 L-L (SW490)
- Batch
- Serial numbers between 190790036E and 190790137E only.
- Description
- Nexus swivel body (SW460) with shackles fitted on both sides. Available in 3 configurations - a combination of one small D shaped and one large bow-shaped shackle (product code SW470), two small D shaped shackles (product code SW480) or two larger bow-shaped shackles (product code SW490).
- Risk
- The swivel has been assembled incorrectly and the two sides of the swivel could become separated in certain circumstances. If coming apart whilst loaded, it could cause the climber to fall and suffer injuries.The product does not comply with the requirements of the Personal Protective Equipment Directive (since 21/04/2018 repealed by the Personal Protective Equipment Regulation) and the relevant European Standard EN 362.
- Measures
- Recall of the product from end users · by the manufacturer
- Recall page
- https://dmmprofessional.com/Recall-Info/Nexus-recall-for-inspection
- Notifying country
- United Kingdom
- Country of origin
- United Kingdom
- Alert type
- Consumer
- Photos
- Photos shown from the Safety Gate server (European Commission); not copied here.
This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.
Other alerts for DMM
- Hobby/sports equipment · United Kingdom Carabiner – DMM 8 Janweek 1 report, 2016 Injuries Serious risk
- Protective equipment · United Kingdom Camming device for rock climbing Dragon Cam – DMM 25 Marweek 12 report, 2011 Injuries Serious risk
- Protective equipment · United Kingdom Camming device - Dragon Cam 6 – DMM 26 Novweek 47 report, 2010 Injuries Serious risk