Skip to content

Kitchen mixer – Tda Electronics “Mini Impastatore”

Serious risk Electric shock

Published by Safety Gate 16 Dec 2014In the weekly report of 26 Dec 2014 (week 51, 2014)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Product
Kitchen mixer
Brand
Tda Electronics
Brand as notified
TDA ELECTRONICS
Name
Mini Impastatore
Type / model
tda 13406c
Batch
8008087569313
Barcode
8008087569313
Description
Mixer with steel whisks and beaters and steel mixing bowl.
Risk
null Part of the plastic casing has been treated with a metallic finish that makes it electrically conductive and is separated from the live parts only by functional insulation. In addition, the internal connections rely on soldered connections and crimps to stay in position and a loose wire could reduce the clearance and creepage distances to the accessible parts made of conductive plastic. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60335.
Measures
  • Withdrawal of the product from the market · from 10 Nov 2014
Notifying country
Italy
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert A12/2094/14
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert A12/2094/14
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2014-051 (XML)
    the copy this page was built fromCC0 1.0