Skip to content

Lighting chain

Serious risk Electric shock

Published by Safety Gate 21 May 2026In the weekly report of 29 May 2026 (week 21, 2026)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked just nowSource: EU Safety Gate
Product
Lighting chain
Type / model
HLED 100-2 / YW-QL100L
Barcode
3856014582844
Barcodes listed
3856014582844 (official alert record)
Description
Lighting chain.
Risk
The product lacks sufficient insulation. Furthermore, the product has insufficient nominal cross-section of the conductors. The creepage and clearance distance between the circuits is insufficient, the user could touch accessible live parts and receive an electric shock. Moreover, due to inadequate insulation, a short circuit could cause a fire. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN 60598-1 and EN 60598-2-20.
Measures
  • Ban on the marketing of the product and any accompanying measures · ordered on the importer · from 7 Apr 2026
  • Withdrawal of the product from the market · ordered on the importer · from 7 Apr 2026
Notifying country
Croatia
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert SR/01501/26Photo 2 of the product in Safety Gate alert SR/01501/26Photo 3 of the product in Safety Gate alert SR/01501/26
Photos shown from the Safety Gate server (European Commission); not copied here.