Skip to content

Particle filter mask – BKJ “KN95 Protective mask”

Serious risk Health risk / other

Published by Safety Gate 22 Jun 2020In the weekly report of 26 Jun 2020 (week 26, 2020)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Product
Particle filter mask
Brand
BKJ
Name
KN95 Protective mask
Type / model
9001
Batch numbers
  • Batches: 2020-4-26 / 2020-4-28 / 2020-4-30
  • Production series: BKJ202004
(official alert record)
Batch as notified
Batches: 2020-4-26 / 2020-4-28 / 2020-4-30Production series: BKJ202004
Description
KN95 protective respiratory filtration half-face mask, corresponding to category FFP2 according to EN 149.
Risk
The particle/filter retention of the material is insufficient (measured value ≤ 94 %), the mask does not properly adapt to the face resulting in a insufficient total filtration capacity (Measured value ≤ 68 %).Consequently, an excessive amount of particles or microorganisms might pass through the mask, increasing the risk of infection if not combined with additional protective measures. The product does not comply with the Personal Protective Equipment Regulation.
Measures
  • Ban on the marketing of the product and any accompanying measures · ordered on the importer · from 26 May 2020
Notifying country
Belgium
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert A12/00913/20Photo 2 of the product in Safety Gate alert A12/00913/20Photo 3 of the product in Safety Gate alert A12/00913/20
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert A12/00913/20
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2020-26 (XML)
    the copy this page was built fromCC0 1.0