Skip to content

Particle filter mask – Placide “FFP2 R D Wiederverwendbare Maske mit Nano-Technologie”

Serious risk Health risk / other

Published by Safety Gate 11 Sep 2022In the weekly report of 12 Aug 2022 (week 32, 2022)Safety Gate noticeJSON
latest report: week 43, 30 Oct 2026checked 2 min agoSource: EU Safety Gate
Product
Particle filter mask
Brand
Placide
Name
FFP2 R D Wiederverwendbare Maske mit Nano-Technologie
Type / model
RY-CR1
Barcode
4260711580000, 4260711580055, 4260711580109, 4260711580116, 4260711580123
Barcodes listed
  • 4260711580000
  • 4260711580055
  • 4260711580109
  • 4260711580116
  • 4260711580123
(official alert record)
Barcode as notified
42607115800004260711580055426071158010942607115801164260711580123
Description
Reusable respiratory protective half-face mask with adjustable ear loops and cotton outer layer, available in at least 7 diff. colours (incl. black, white, pink, blue, green, each w. different barcode), with "FFP2" and the CE mark printed on. Product sold online, in particular via Amazon and eBay.
Risk
After washing, the particle/filter retention capacity of the material reduces significantly (measured values: as low as 69%). Furthermore, the product contains erroneous indications regarding its use, reducing its protective function. Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect. The product does not comply with the Personal Protective Equipment Regulation nor with the European standard EN 149.
Measures
  • Stop of sales · by the importer · from 26 Jul 2022
  • Warning consumers of the risks · by the importer
Recall page
https://mask24.net/pages/sicherheitshinweis-179179
Online marketplace
Amazon, eBay
Notifying country
Germany
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert A12/01156/22Photo 2 of the product in Safety Gate alert A12/01156/22Photo 3 of the product in Safety Gate alert A12/01156/22Photo 4 of the product in Safety Gate alert A12/01156/22Photo 5 of the product in Safety Gate alert A12/01156/22Photo 6 of the product in Safety Gate alert A12/01156/22
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert A12/01156/22
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2022-32 (XML)
    the copy this page was built fromCC0 1.0