Product
Electric incense burner
Type / model
WL-05D
Description
Electric incense burner. Voltage of 220-240 V. All batches are concerned.
Risk
The appliance is not earthed. In addition, its conductors are not held in position, the accessible metal parts are not sufficiently insulated from the live parts, in particular the conductors of the power supply cable, and the clearance /creepage distances between the live parts of the heating element and the accessible metal part are insufficient. The user may therefore touch live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive.
Measures
  • Withdrawal of the product from the market · by the importer
  • Recall of the product from end users · by the importer · from 2 Feb 2026
Recall page
https://rappel.conso.gouv.fr
Notifying country
France
Country of origin
People's Republic of China
Alert type
Consumer
Photos
Photo 1 of the product in Safety Gate alert SR/02158/26Photo 2 of the product in Safety Gate alert SR/02158/26Photo 3 of the product in Safety Gate alert SR/02158/26Photo 4 of the product in Safety Gate alert SR/02158/26
Photos shown from the Safety Gate server (European Commission); not copied here.

This page reproduces the Safety Gate record as published. recallarchive is not affiliated with the European Commission. If you own this product, follow the measures above and contact the seller.

Sources

  1. Safety Gate alert SR/02158/26
    European Commission, Safety Gaterecord fields marked “official alert record”: © European Union, CC BY 4.0; values listed separately here
  2. Safety Gate weekly report Report-2026-31 (XML)
    the copy this page was built fromCC0 1.0